Datalogic-scanning Pegaso Manual do Utilizador Página 122

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 172
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 121
Programming Parameters
F-14
Pegaso™ Industrial PDA with Windows
®
CE
Table F-3. Other Controls
Code Parameter/ Description I.D. #
Acceptable
Input
Defaults
Min Max Factory
Other Controls
Enter 1 for On and 0 for Off.
Enable Label
Programming
Enables/disables the ability to per-
form label programming.
FF00 On / Off On On On
Beeper Volume
Adjusts the beeper volume. FF20
00 = Off
00
- 09
(01 = Lowest;
07 = Highest;
08 = Higher;
09 = Lower)
07 07 07
Long Range
Trigger Mode
Selects the Long Range Trigger
mode.
0000
On = Release
Scan Off
=
Spot Timeout
Off Off Off
Spotting Beam
Enable
Enables/disables the Spotting Beam 0001 On / Off On On On
Spotting Beam
Timeout
Sets the duration of the spotting
beam before it automatically turns off.
0023
00 = 0.25 sec.
01
= 0.5 sec.
02 = 1.0 sec.
03 = 1.5 sec.
04 = 2.0 sec.
01 01 01
Release Scan
Timeout
Sets the duration of the scan before it
turns off.
0024 1-10 02 02 02
Number of
Good-Read
Beeps
Determines the number of beeps for
a good read indicator.
0020 01 - 04 01 01 01
Good-Read
Beep Tone
Adjusts the pitch of the beeper fre-
quency.
0021
00 - 07
(0
0 = Lowest;
07 = Highest)
00 00 00
Good-Read
Beep Duration
Determines the duration of a good
read beep.
0022
00 = 0.07 sec.
0
1 = 0.13 sec.
02 = 0.18 sec.
03 = 0.36 sec.
00 00 00
Send Symbol-
ogy Identifiers
Specifies the symbology identifier (if
any) that is sent by the decoder when
parameter Send Code ID (Index
0025) is set to 3. "ASCII" code zero
(null) used to indicate an identifier not
to be sent
for the symbology.
0025
00 = Off
01
= DLM IDs*
02 = AIM IDs
03 = User IDs
00 01 00