Datalogic Scanning Controller SC6000 Manual do Utilizador Página 50

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
Vista de página 49
SC6000
A
V
PS/PS AUX ENCODER
Ground
SC6000
A/B
B/
A
GND
V
S_INPUTS*
Signal
PWO
V
S
V
S
PSIN
+ 5V
~
~
+
-
*VS_INPUTS is connected through the 25-pin Extended I/O connector. If this connector is not used, VS_INPUTS
must be wired from one of the scanner terminals inside PWO, see the PWO Reference Manual for details.
Figure 38 - PNP Command Input Using System Power
V
PS/PS AUX ENCODER
Ground
SC6000
A/B
B/
A
GND
V
S_INPUTS*
Signal
PWO
V
S
V
S
PSIN
+ 5V
~
~
+
-
*VS_INPUTS is connected through the 25-pin Extended I/O connector. If this connector is not used, VS_INPUTS
must be wired from one of the scanner terminals inside PWO, see the PWO Reference Manual for details.
Figure 39 - NPN Command Input Using System Power