www.automation.datalogic.comC-BOX 150Installation Manual
C-BOX 150 1 1.2 C-BOX 150 COMPATIBLE DEVICES The C-BOX 150 can be connected to the following scanners through the 25-pin connector illustrated in F
INSTALLATION 2 2 INSTALLATION 2.1 PACKAGE CONTENTS Verify that the C-BOX 150 and all the parts supplied with the equipment are present and intact w
C-BOX 150 2 2.2 OPENING THE DEVICE To install the C-BOX 150 or during normal maintenance, it is necessary to open it by unscrewing the four cover s
INSTALLATION 2 2.3 MECHANICAL INSTALLATION The diagram below gives the overall dimensions of the C-BOX 150 and may be used for its installation. m
C-BOX 150 2 C-BOX 150 can be installed to operate in different positions. The two screw holes inside the housing of the C-BOX 150 are for mechanical
INSTALLATION 2 2.4 ELECTRICAL CONNECTIONS AND HARDWARE SETUP The following figure shows the typical layout. SCANNER AUXILIARY INTERFACEC-BOX 150SC
C-BOX 150 2 After system functioning has been verified, close the C-BOX 150 using the 4 cover screws making sure the rubber seal is fitted correctly
INSTALLATION 2 C-BOX12VSGNDUSER INTERFACEGNDV+ (10 - 30 Vdc) Figure 7 - Power Supply Connections The power supply must be between 10 and 30 Vdc only
C-BOX 150 2 • Using a device such as a screwdriver, push down on the lever directly next to the clamp (see Figure 8). • Insert the wire into the cl
INSTALLATION 2 The C-BOX 150 spring clamp connector pinouts are indicated in the following table. Refer to the scanner Reference Manual for details.
Datalogic Automation S.r.l. Via S. Vitalino 13 40012 - Lippo di Calderara di Reno Bologna - Italy C-BOX 150 Ed.: 07/2007
C-BOX 150 2 2.4.3 Scanner Chassis Grounding Jumper Settings The scanner chassis grounding method can be selected by positioning a jumper (see Figur
INSTALLATION 2 2.4.5 RS485 Bus Termination ON OFF Figure 11 - Termination Resistance Switch This switch enables or disables the insertion of t
C-BOX 150 2 2.4.7 OM4000 Jumper Settings J6J5Figure 13 - OM4000 Jumpers The jumpers allow connection to the EXT TRIG signals on separate spring c
INSTALLATION 2 9-pin C-Box 150 connector pinout in Normal mode Pin Name Function 1 NC 2 RXA Auxiliary RS232 3 TXA Auxiliary RS232 4 NC 5 GND
C-BOX 150 2 2.5 OPERATING MODES With the C-BOX 150, the following operating modes are possible: Normal Operation: At power on, the C-BOX 150 tries
INSTALLATION 2 2. Release the buttons. 3. Press the left button corresponding to the GET function, the center button corresponding to the TEST funct
C-BOX 150 2 2.5.2 LED Indicators Warning (red) Pow n)er on (greePower polarity error (red) TX (green) Status(yellow)Figure 16 - LED Indicators
INSTALLATION 2 1 blinking/sec: a requested operation has been terminated abnormally. 2 blinking/sec: a wrong operation has been requested (for example
C-BOX 150 2 2.6 TYPICAL LAYOUTS 2.6.1 1000, 2000A/N, 4000 Family Scanners For 1000, 2000A/N and 4000 scanner families which operate in a point-to
INSTALLATION 2 2.6.2 2000N Family Scanners For 2000N scanner families which operate in an ID-NET™ network configuration, a typical layout is shown b
CONTENTS 1 INTRODUCTION ... 1 1.1 Product Description...
C-BOX 150 2 2.6.3 6000, 8000 Family Scanners For the 6000 and 8000 scanner families, the C-BOX 150 can operate in both point-to-point single scanne
INSTALLATION 2 In order to perform Backup/Restore of Master only, the C-BOX 150 Cluster GET/SEND parameter must be configured to "Master only&quo
C-BOX 150 3 3 TECHNICAL FEATURES ELECTRICAL FEATURES Power Supply voltage 10 to 30 Vdc Power consumption max. 2.5 W + scanner USER INTERFACE
DECLARATION OF CONFORMITY 07 Datalogic Automation S.r.l., Via S. Vitalino 13 40012 - Lippo di Calderara Bologna - Italy dichiara che declares that
www.automation.datalogic.comC-BOX 150Installation Manual
SAFETY PRECAUTIONS POWER SUPPLY ATTENTION: READ THIS INFORMATION BEFORE INSTALLING THE PRODUCT - This product is intended to be installed by Qua
ITALIANO Informazione degli utenti ai sensi della Direttiva Europea 2002/96/EC L’apparecchiatura che riporta il simbolo del bidone barrato deve esse
GENERAL VIEW C-BOX 150 23 1 Figure A 25-pin scanner connectorCover screws (4) Compression connectors1 2 3 vi
C-BOX 150 92 1112 7815 1 17 18 4 5 1013 6316 14 Figure B - Bottom Inside Power on switch 1 2 Chassis grounding jumper 3 Power polarity error
GUIDE TO INSTALLATION The following can be used as a checklist to verify all of the steps necessary for complete installation of the C-BOX 150. 1)
INTRODUCTION 1 1 INTRODUCTION 1.1 PRODUCT DESCRIPTION The C-BOX 150 is a connection box which can be used as an accessory to several Datalogic fami