MATRIX 400™ REFERENCE MANUAL
10
1
Learn
8. Enter the Learn function by pressing and holding
the X-PRESS™ push button until the Learn LED is
on.
9. Release the button to enter the Learn function.
The Learn LED will blink until the procedure is
completed.
The Learn procedure ends when the Image
Processing and Decoding parameters are
successfully saved in the reader memory, the
Learn LED will remain on continuously, the Green
Spot is activated and Matrix 400™ emits 3 high
pitched beeps.
If the calibration cannot be reached after a timeout
of about 3 (three) minutes Matrix 400™ will exit
without saving the parameters to memory, the
Learn LED will not
remain on continuously but it will
just stop blinking. In this case Matrix 400™ emits a
long low pitched beep.
10. Exit the Setup function by pressing the X-
PRESS™ push button once.