Datalogic Scanning QuickScan QD2100 Manual do Utilizador

Consulte online ou descarregue Manual do Utilizador para Leitores de códigos de barras Datalogic Scanning QuickScan QD2100. Datalogic Scanning QUICKSCAN QD2100 User's Manual Manual do Utilizador

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 320
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes

Resumo do Conteúdo

Página 1 - QuickScan

QuickScan®iQD2100 Barcode ImagerProduct Reference Guide

Página 2

Introduction2 QuickScan® QD2100Chapter 11, Symbologies defines options for all symbologies and provides the program-ming barcodes necessary for config

Página 3 - Table of Contents

Data Editing92 QuickScan® QD2100Global AIM IDAIM label identifiers (as opposed to custom characters you select yourself as with label identifiers) can

Página 4

Global AIM IDProduct Reference Guide 93Global AIM ID — continuedENTER/EXIT PROGRAMMING MODEGlobal AIM ID = DisableGlobal AIM ID = EnableDEFAU

Página 5

Data Editing94 QuickScan® QD2100GS1-128 AIM IDIf Global AIM ID is disabled, the AIM ID for GS1-128 can be enabled/disabled inde-pendently. The AIM ID

Página 6

Label IDProduct Reference Guide 95Label IDA Label ID is a customizable code of up to three ASCII characters (each can be one ofhex 0x01-0xFF)

Página 7

Data Editing96 QuickScan® QD2100Table 17. Label ID Pre-loaded SetsSymbology Default Label ID set Alternate Label ID setASCIIcharacterHexidecimalvalueA

Página 8

Label IDProduct Reference Guide 97S25 s 730000 P 500000UPCAA 410000 C 430000UPCA P2A 410000 F 460000UPCA P5A 410000 G 470000UPCA P8A 410000 Q

Página 9 - Introduction

Data Editing98 QuickScan® QD2100Label ID: Set Individually Per SymbologyTo configure a Label ID individually for a single symbology:1. Scan the ENTER/

Página 10 - References

Label IDProduct Reference Guide 99Label ID — continuedTable 18. Label ID ExamplesSTEP ACTION EXAMPLES1. Scan the ENTER/EXIT barcode (Scanner

Página 11 - Technical Support

Data Editing100 QuickScan® QD2100Label ID — continuedLabel ID ControlThis option controls whether a Label ID is disabled, or sent as a prefix or suffi

Página 12 - 4 QuickScan® QD2100

Label IDProduct Reference Guide 101Label ID — continuedLabel ID Symbology SelectionThis option selects the symbology for which a Label ID is

Página 13 - Getting Started

Technical SupportProduct Reference Guide 3Technical SupportDatalogic Website SupportThe Datalogic website (www.scanning.datalogic.com) is the

Página 14 - Disconnecting at

Data Editing102 QuickScan® QD2100Label ID — continuedLabel ID Symbology Selection — continuedThis option selects the symbology for which a Label ID is

Página 15 - Programming

Label IDProduct Reference Guide 103Label ID — continuedLabel ID Symbology Selection — continuedThis option selects the symbology for which a

Página 16 - Configure Other Features

Data Editing104 QuickScan® QD2100Label ID — continuedLabel ID Symbology Selection — continuedThis option selects the symbology for which a Label ID is

Página 17 - Standard Product Default Set

Label IDProduct Reference Guide 105Label ID — continuedLabel ID Symbology Selection — continuedThis option selects the symbology for which a

Página 18 - 10 QuickScan® QD2100

Data Editing106 QuickScan® QD2100Label ID — continuedLabel ID Symbology Selection — continuedThis option selects the symbology for which a Label ID is

Página 19 - Interfaces

Case ConversionProduct Reference Guide 107Case ConversionThis feature allows conversion of the case of all alphabetic characters to upper or

Página 20 - Select RS-232 OPOS

Data Editing108 QuickScan® QD2100Character ConversionCharacter conversion is an eight byte configuration item. The eight bytes are 4 character pairs r

Página 21 - Configuring the Interface

Character ConversionProduct Reference Guide 109Character Conversion — continuedENTER/EXIT PROGRAMMING MODEConfigure Character ConversionDEFAU

Página 22 - 14 QuickScan® QD2100

Data Editing110 QuickScan® QD2100NOTES

Página 23 - Global Interface Features

Product Reference Guide 111Chapter 11SymbologiesIntroductionThe reader supports the following symbologies (barcode types). Options for each sym-bology

Página 24 - USB Suspend Mode

Introduction4 QuickScan® QD2100NOTES

Página 25 - General Features

Symbologies112 QuickScan® QD2100UPC-AThe following options apply to the UPC-A symbology.UPC-A Enable/DisableWhen disabled, the reader will not read UP

Página 26 - 18 QuickScan® QD2100

UPC-AProduct Reference Guide 113UPC-A — cont.Expand UPC-A to EAN-13Expands UPC-A data to the EAN-13 data format. Selecting this feature also

Página 27 - Label Gone Timeout

Symbologies114 QuickScan® QD2100UPC-A — cont.In-Store Minimum ReadsThis feature specifies the minimum number of consecutive times an in-store label mu

Página 28 - Label Gone Timeout — cont

UPC-EProduct Reference Guide 115UPC-EThe following options apply to the UPC-E symbology.UPC-E Enable/DisableWhen disabled, the reader will no

Página 29 - LED and Beeper Indicators

Symbologies116 QuickScan® QD2100UPC-E — cont.Expand UPC-E to EAN-13Expands UPC-E data to the EAN-13 data format. Selecting this feature also changes t

Página 30 - Good Read: When to Indicate

UPC-EProduct Reference Guide 117UPC-E — cont.UPC-E Number System Character TransmissionThis feature enables/disables transmission of the UPC-

Página 31 - Good Read Beep Type

Symbologies118 QuickScan® QD2100UPC-E — cont.UPC-E Minimum ReadsThis feature specifies the minimum number of consecutive times a UPC-E label must be d

Página 32 - Good Read Beep Length

GTIN FormattingProduct Reference Guide 119GTIN FormattingThis feature enables/disables the ability to convert UPC-E, UPC-A, EAN 8, and EAN 13

Página 33

Symbologies120 QuickScan® QD2100EAN 13The following options apply to the EAN 13 (Jan 13) symbology.EAN 13 Enable/DisableWhen disabled, the reader will

Página 34 - Good Read Beep Volume

EAN 13Product Reference Guide 121EAN 13 — cont.EAN-13 Flag 1 CharacterEnables/disables transmission of an EAN/JAN13 Flag1 character. The Flag

Página 35 - Good Read LED Duration

Product Reference Guide 5Chapter 2Getting StartedAbout the ImagerAdvancements in the LED technology used in this imager significantly improve the illu

Página 36 - 2 seconds

Symbologies122 QuickScan® QD2100EAN-13 ISBN ConversionThis option enables/disables conversion of EAN 13/JAN 13 Bookland labels starting with 978 to IS

Página 37 - Scanning Features

EAN 13Product Reference Guide 123EAN 13 — cont.EAN 13 Minimum ReadsThis feature specifies the minimum number of consecutive times an EAN 13 l

Página 38 - Scan Mode — continued

Symbologies124 QuickScan® QD2100EAN 8The following options apply to the EAN 8 (Jan 8) symbology.EAN 8 Enable/DisableWhen disabled, the reader will not

Página 39 - Stand Mode Triggered Timeout

EAN 8Product Reference Guide 125EAN 8 — cont.Expand EAN 8 to EAN 13Enable this option to expand EAN 8/JAN 8 labels to EAN 13/JAN 13.ENTER/EXI

Página 40 - 32 QuickScan® QD2100

Symbologies126 QuickScan® QD2100EAN 8 — cont.EAN 8 Minimum ReadsThis feature specifies the minimum number of consecutive times an EAN 8 (Jan 8) label

Página 41 - Scanning Active Time

UPC/EAN Global SettingsProduct Reference Guide 127UPC/EAN Global SettingsThis section provides configuration settings for UPC-A, UPC-E, EAN 1

Página 42 - Scanning Active Time — cont

Symbologies128 QuickScan® QD2100UPC/EAN Global Settings — cont.UPC/EAN Decoding Level — cont.ENTER/EXIT PROGRAMMING MODEUPC/EAN Decoding Level = 1UPC/

Página 43 - Flash On Time

UPC/EAN Global SettingsProduct Reference Guide 129UPC/EAN Global Settings — cont.UPC/EAN CorrelationWhen correlation is enabled, the barcode

Página 44 - Flash On Time — cont

Symbologies130 QuickScan® QD2100UPC/EAN Global Settings — cont.UPC/EAN Price Weight CheckThis feature enables/disables calculation and verification of

Página 45 - Flash Off Time

UPC/EAN Global SettingsProduct Reference Guide 131UPC/EAN Global Settings — cont.UPC-A Minimum ReadsThis feature specifies the minimum number

Página 46 - Flash Off Time — cont

Getting Started6 QuickScan® QD2100Setting Up the ImagerFollow the steps provided in this section to connect and get your imager up and commu-nicating

Página 47 - Stand Mode Sensitivity

Symbologies132 QuickScan® QD2100Add-OnsThe following features apply to optional add-ons.Optional Add-onsThe reader can be enabled to optionally read t

Página 48 - Green Spot Duration

Add-OnsProduct Reference Guide 133Add-Ons — cont.Optional Add-ons — cont.ENTER/EXIT PROGRAMMING MODEOptional Add-Ons = Enable P5Optional Add-

Página 49 - RS-232 ONLY Interface

Symbologies134 QuickScan® QD2100Add-Ons — cont.Optional Add-On TimerThis option sets the time the reader will look for an add-on when an add-on fragme

Página 50 - Baud Rate — continued

Add-OnsProduct Reference Guide 135Add-Ons — cont.Optional Add-On Timer — cont.ENTER/EXIT PROGRAMMING MODEOptional Add-on Timer = 60msOptional

Página 51 - Data Bits

Symbologies136 QuickScan® QD2100Add-Ons — cont.Optional Add-On Timer — cont.ENTER/EXIT PROGRAMMING MODEOptional Add-on Timer = 180msOptional Add-on Ti

Página 52 - Stop Bits

Add-OnsProduct Reference Guide 137Add-Ons — cont.Optional GS1-128 Add-On TimerThis option sets the timer expiration value to read the additio

Página 53 - Parity = Odd

Symbologies138 QuickScan® QD2100Add-Ons — cont.Optional GS1-128 Add-On Timer — cont.ENTER/EXIT PROGRAMMING MODEOptional GS1-128 Add-On Timer = 60msOpt

Página 54 - Handshaking Control

Add-OnsProduct Reference Guide 139Add-Ons — cont.Optional GS1-128 Add-On Timer — cont.ENTER/EXIT PROGRAMMING MODEOptional GS1-128 Add-On Time

Página 55 - RS-232/USB-Com Interfaces

Symbologies140 QuickScan® QD2100Add-Ons — cont.P2 Add-Ons Minimum ReadsThis feature specifies the minimum number of times a P2 add-on must be read bef

Página 56 - Intercharacter Delay

Add-OnsProduct Reference Guide 141Add-Ons — cont.P5 Add-Ons Minimum ReadsThis feature specifies the minimum number of times a P5 add-on must

Página 57 - Intercharacter Delay — cont

Setting Up the ImagerProduct Reference Guide 7USB Connection — Connect the imager to a USB port on the terminal/PC using the correct USB cab

Página 58 - Beep On Not on File

Symbologies142 QuickScan® QD2100Add-Ons — cont.GS1-128 Add-Ons Minimum ReadsThis feature specifies the minimum number of times an GS1-128 add-on must

Página 59 - ACK NAK Options

GS1 DataBar OmnidirectionalProduct Reference Guide 143GS1 DataBar OmnidirectionalThe following options apply to the GS1 DataBar Omnidirection

Página 60 - ACK Character

Symbologies144 QuickScan® QD2100GS1 DataBar Omnidirectional — cont.GS1 DataBar Omnidirectional Minimum ReadsThis feature specifies the minimum number

Página 61 - ACK Character — cont

GS1 DataBar ExpandedProduct Reference Guide 145GS1 DataBar ExpandedThe following options apply to the GS1 DataBar Expanded (formerly RSS Expa

Página 62 - NAK Character

Symbologies146 QuickScan® QD2100GS1 DataBar Expanded — cont.GS1 DataBar Expanded Minimum ReadsThis feature specifies the minimum number of consecutive

Página 63 - NAK Character — cont

GS1 DataBar ExpandedProduct Reference Guide 147GS1 DataBar Expanded — cont.GS1 DataBar Expanded Length ControlThis feature specifies either v

Página 64 - ACK NAK Timeout Value

Symbologies148 QuickScan® QD2100GS1 DataBar Expanded — cont.GS1 DataBar Expanded Set Length 1This feature specifies one of the barcode lengths for GS1

Página 65 - ACK NAK Timeout Value — cont

GS1 DataBar ExpandedProduct Reference Guide 149GS1 DataBar Expanded — cont.GS1 DataBar Expanded Set Length 1 — cont.ENTER/EXIT PROGRAMMING MO

Página 66 - ACK NAK Retry Count

Symbologies150 QuickScan® QD2100GS1 DataBar Expanded — cont.GS1 DataBar Expanded Set Length 2This feature specifies one of the barcode lengths for GS1

Página 67 - ACK NAK Retry Count — cont

GS1 DataBar ExpandedProduct Reference Guide 151GS1 DataBar Expanded — cont.GS1 DataBar Expanded Set Length 2 — cont.ENTER/EXIT PROGRAMMING MO

Página 68 - ACK NAK Error Handling

Getting Started8 QuickScan® QD2100Using the Programming BarcodesThis manual contains feature descriptions and barcodes which allow you to reconfigure

Página 69 - Indicate Transmission Failure

Symbologies152 QuickScan® QD2100GS1 DataBar LimitedThe following options apply to the GS1 DataBar Limited (formerly RSS Limited) sym-bology.GS1 DataBa

Página 70 - Disable Character

GS1 DataBar LimitedProduct Reference Guide 153GS1 DataBar Limited — cont.GS1 DataBar Limited Minimum ReadsThis feature specifies the minimum

Página 71 - Disable Character — cont

Symbologies154 QuickScan® QD2100Code 39The following options apply to the Code 39 symbology.Code 39 Enable/DisableWhen disabled, the reader will not r

Página 72 - Enable Character

Code 39Product Reference Guide 155Code 39 — cont.Code 39 Check Character CalculationEnable this option to enables/disables calculation and ve

Página 73 - Enable Character — cont

Symbologies156 QuickScan® QD2100Code 39 — cont.Code 39 Check Character TransmissionEnable this option to transmit the check character along with Code

Página 74 - 66 QuickScan® QD2100

Code 39Product Reference Guide 157Code 39 — cont.Code 39 Full ASCIIIn Code 39 decoding, this enables/disables the translation of Code 39 char

Página 75 - Keyboard Interface

Symbologies158 QuickScan® QD2100Code 39 — cont.Code 39 Quiet ZonesThis feature specifies the number of quiet zones for Code 39 labels. Quiet zones are

Página 76 - Country Mode

Code 39Product Reference Guide 159Code 39 — cont.Code 39 Minimum ReadsThis feature specifies the minimum number of consecutive times a Code 3

Página 77 - Country Mode — continued

Symbologies160 QuickScan® QD2100Code 39 — cont.Code 39 Decoding LevelDecoding Levels are used to configure a barcode symbology decoder to be very aggr

Página 78

Code 39Product Reference Guide 161Code 39 — cont.Code 39 Decoding Level — cont.ENTER/EXIT PROGRAMMING MODECode 39 Decoding Level = 1Code 39 D

Página 79 - Caps Lock State

Resetting the Standard Product DefaultsProduct Reference Guide 9Resetting the Standard Product DefaultsIf you aren’t sure what programming op

Página 80 - Send Control Characters

Symbologies162 QuickScan® QD2100Code 39 — cont.Code 39 Length ControlThis feature specifies either variable length decoding or fixed length decoding f

Página 81 - Wedge Quiet Interval

Code 39Product Reference Guide 163Code 39 — cont.Code 39 Set Length 1This feature specifies one of the barcode lengths for Code 39 Length Con

Página 82 - Wedge Quiet Interval — cont

Symbologies164 QuickScan® QD2100Code 39 — cont.Code 39 Set Length 1 — cont.ENTER/EXIT PROGRAMMING MODESelect Code 39 Set Length 1 SettingMake a mistak

Página 83

Code 39Product Reference Guide 165Code 39 — cont.Code 39 Set Length 2This feature specifies one of the barcode lengths for Code 39 Length Con

Página 84

Symbologies166 QuickScan® QD2100Code 39 — cont.Code 39 Set Length 2 — cont.ENTER/EXIT PROGRAMMING MODESelect Code 39Length 2 SettingMake a mistake? Sc

Página 85 - Intercode Delay

Code 39Product Reference Guide 167Code 39 — cont.Code 39 Interdigit RatioThis feature specifies the ratio between an intercharacter space and

Página 86 - Intercode Delay — cont

Symbologies168 QuickScan® QD2100Code 39 — cont.Code 39 Interdigit Ratio — cont.ENTER/EXIT PROGRAMMING MODECode 39 Interdigit Ratio = 6Code 39 Interdig

Página 87 - USB Keyboard Speed

Code 39Product Reference Guide 169Code 39 — cont.Code 39 Character CorrelationWhen correlation is enabled, the barcode reader will combine la

Página 88 - 80 QuickScan® QD2100

Symbologies170 QuickScan® QD2100Code 39 StitchingThis option enables/disables stitching for Code 39 labels. When parts of a Code 39 bar-code are prese

Página 89 - USB-OEM Interface

Code 32Product Reference Guide 171Code 32The following options apply to the Code 32 (Italian Pharamaceutical Code) symbology.Code 32 Enable/D

Página 90 - USB-OEM Device Usage

Getting Started10 QuickScan® QD2100NOTES

Página 91 - IBM 46XX Interface

Symbologies172 QuickScan® QD2100Code 32 — cont.Code 32 Check Character TransmissionEnable this option to transmit the check character along with Code

Página 92 - 46xx Number of Host Resets

Code 128Product Reference Guide 173Code 128The following options apply to the Code 128 symbology.Code 128 Enable/DisableWhen disabled, the re

Página 93

Symbologies174 QuickScan® QD2100Code 128 — cont.Code 128 Check Character TransmissionEnable this option to transmit the check character along with Cod

Página 94 - 86 QuickScan® QD2100

Code 128Product Reference Guide 175Code 128 — cont.Code 128 Sub-Code Change Transmission Enables/disables the transmission of “Sub-Code excha

Página 95 - Code 39 Format —

Symbologies176 QuickScan® QD2100Code 128 — cont.Code 128 Quiet ZonesThis feature specifies the number of quiet zones for Code 128 labels. Quiet zones

Página 96 - 88 QuickScan® QD2100

Code 128Product Reference Guide 177Code 128 — cont.Code 128 Minimum ReadsThis feature specifies the minimum number of consecutive times a Cod

Página 97 - Chapter 10

Symbologies178 QuickScan® QD2100Code 128 — cont.Code 128 Decoding LevelDecoding Levels are used to configure a barcode symbology decoder to be very ag

Página 98 - 00 - 20 Characters (ASCII)

Code 128Product Reference Guide 179Code 128 — cont.Code 128 Decoding Level — cont.ENTER/EXIT PROGRAMMING MODECode 128 Decoding Level = 1Code

Página 99 - Global Suffix = 0x0D (CR)

Symbologies180 QuickScan® QD2100Code 128 — cont.Code 128 Length ControlThis feature specifies either variable length decoding or fixed length decoding

Página 100 - Global AIM ID

Code 128Product Reference Guide 181Code 128 — cont.Code 128 Set Length 1This feature specifies one of the barcode lengths for Code 128 Length

Página 101 - Global AIM ID — continued

Product Reference Guide 11Chapter 3InterfacesInterface SelectionEach reader model will support one of the following sets of host interfaces:General Pu

Página 102 - GS1-128 AIM ID

Symbologies182 QuickScan® QD2100Code 128 — cont.Code 128 Set Length 1 — cont.ENTER/EXIT PROGRAMMING MODESelect Code 128 Set Length 1 SettingMake a mis

Página 103 - Label ID

Code 128Product Reference Guide 183Code 128 — cont.Code 128 Set Length 2This feature specifies one of the barcode lengths for Code 128 Length

Página 104 - 96 QuickScan® QD2100

Symbologies184 QuickScan® QD2100Code 128 — cont.Code 128 Set Length 2 — cont.ENTER/EXIT PROGRAMMING MODESelect Code 128 Length 2 SettingMake a mistake

Página 105

Code 128Product Reference Guide 185Code 128 — cont.Code 128 Character CorrelationWhen correlation is enabled, the barcode reader will combine

Página 106 - Data Editing

Symbologies186 QuickScan® QD2100Code 128 — cont.Code 128 StitchingThis option enables/disables stitching for Code 128 labels. When parts of a Code 128

Página 107 - Label ID — continued

GS1-128Product Reference Guide 187GS1-128The following options apply to the GS1-128 symbology. (Also known as USS-128, GTIN-128, UCC-128.)GS1

Página 108

Symbologies188 QuickScan® QD2100Interleaved 2 of 5 (I 2 of 5)The following options apply to the I 2 of 5 symbology.I 2 of 5 Enable/DisableWhen disable

Página 109

Interleaved 2 of 5 (I 2 of 5)Product Reference Guide 189Interleaved 2 of 5 (I 2 of 5) — cont.I 2 of 5 Check Character CalculationThis option

Página 110

Symbologies190 QuickScan® QD2100Interleaved 2 of 5 (I 2 of 5) — cont.I 2 of 5 Check Character TransmissionEnable this option to transmit the check cha

Página 111

Interleaved 2 of 5 (I 2 of 5)Product Reference Guide 191Interleaved 2 of 5 (I 2 of 5) — cont.I 2 of 5 Minimum ReadsThis feature specifies the

Página 112

Datalogic Scanning, Inc.959 Terry StreetEugene, Oregon 97402Telephone: (541) 683-5700Fax: (541) 345-7140An Unpublished Work - All rights reserved. No

Página 113

Interfaces12 QuickScan® QD2100Table 1. Available InterfacesRS-232 FEATURESRS-232 standard interfaceSelect RS232-STDSet RS-232 InterfaceFeaturesstartin

Página 114

Symbologies192 QuickScan® QD2100Interleaved 2 of 5 (I 2 of 5) — cont.2 of 5 Decoding LevelDecoding Levels are used to configure a barcode symbology de

Página 115 - Case Conversion

Interleaved 2 of 5 (I 2 of 5)Product Reference Guide 193Interleaved 2 of 5 (I 2 of 5) — cont.2 of 5 Decoding Level — cont.ENTER/EXIT PROGRAMM

Página 116 - Character Conversion

Symbologies194 QuickScan® QD2100Interleaved 2 of 5 (I 2 of 5) — cont.I 2 of 5 Length ControlThis feature specifies either variable length decoding or

Página 117 - ENTER/EXIT PROGRAMMING MODE

Interleaved 2 of 5 (I 2 of 5)Product Reference Guide 195Interleaved 2 of 5 (I 2 of 5) — cont.I 2 of 5 Set Length 1This feature specifies one

Página 118 - 110 QuickScan® QD2100

Symbologies196 QuickScan® QD2100Interleaved 2 of 5 (I 2 of 5) — cont.Datalogic 2 of 5 Set Length 1 — cont.ENTER/EXIT PROGRAMMING MODESelect I 2 of 5 L

Página 119 - Symbologies

Interleaved 2 of 5 (I 2 of 5)Product Reference Guide 197Interleaved 2 of 5 (I 2 of 5) — cont.I 2 of 5 Set Length 2This feature specifies one

Página 120 - UPC-A Enable/Disable

Symbologies198 QuickScan® QD2100Interleaved 2 of 5 (I 2 of 5) — cont.I 2 of 5 Set Length 2 — cont.ENTER/EXIT PROGRAMMING MODESelect I 2 of 5 Length 2

Página 121 - UPC-A — cont

Interleaved 2 of 5 (I 2 of 5)Product Reference Guide 199Interleaved 2 of 5 (I 2 of 5) — cont.I 2 of 5 Character CorrelationWhen correlation i

Página 122

Symbologies200 QuickScan® QD2100Interleaved 2 of 5 (I 2 of 5) — cont.I 2 of 5 StitchingThis option enables/disables stitching for I 2 of 5 labels. Whe

Página 123 - UPC-E Enable/Disable

Datalogic 2 of 5Product Reference Guide 201Datalogic 2 of 5The following options apply to the Datalogic 2 of 5 symbology.Datalogic 2 of 5 Ena

Página 124 - UPC-E — cont

Configuring the InterfaceProduct Reference Guide 13KEYBOARD FEATURESAT, PS/2 25-286, 30-286, 50, 50Z, 60, 70, 80, 90 & 95w/Standard Key E

Página 125

Symbologies202 QuickScan® QD2100Datalogic 2 of 5 — cont.Datalogic 2 of 5 Check Character CalculationThis option enables/disables calculation and verif

Página 126

Datalogic 2 of 5Product Reference Guide 203Datalogic 2 of 5 — cont.Datalogic 2 of 5 Minimum ReadsThis feature specifies the minimum number of

Página 127 - GTIN Formatting

Symbologies204 QuickScan® QD2100Datalogic 2 of 5 — cont.Datalogic 2 of 5 Length ControlThis feature specifies either variable length decoding or fixed

Página 128 - EAN 13 Enable/Disable

Datalogic 2 of 5Product Reference Guide 205Datalogic 2 of 5 — cont.Datalogic 2 of 5 Set Length 1This feature specifies one of the barcode len

Página 129 - EAN 13 — cont

Symbologies206 QuickScan® QD2100Datalogic 2 of 5 — cont.Datalogic 2 of 5 Set Length 1 — cont.ENTER/EXIT PROGRAMMING MODESelect Datalogic 2 of 5 Length

Página 130 - EAN-13 ISBN Conversion

Datalogic 2 of 5Product Reference Guide 207Datalogic 2 of 5 — cont.Datalogic 2 of 5 Set Length 2This feature specifies one of the barcode len

Página 131

Symbologies208 QuickScan® QD2100Datalogic 2 of 5 — cont.Datalogic 2 of 5 Set Length 2 — cont.ENTER/EXIT PROGRAMMING MODESelect Datalogic 2 of 5 Length

Página 132 - EAN 8 Enable/Disable

Datalogic 2 of 5Product Reference Guide 209Datalogic 2 of 5 Interdigit Maximum RatioThis feature specifies the maximum ratio between intercha

Página 133 - EAN 8 — cont

Symbologies210 QuickScan® QD2100Datalogic 2 of 5 Interdigit Maximum Ratio — cont.Datalogic 2 of 5 Interdigit Maximum Ratio = 6Datalogic 2 of 5 Interdi

Página 134

Datalogic 2 of 5Product Reference Guide 211Datalogic 2 of 5 — cont.Datalogic 2 of 5 Character CorrelationWhen correlation is enabled, the bar

Página 135 - UPC/EAN Global Settings

Interfaces14 QuickScan® QD2100KEYBOARD — cont. FEATURESKeyboard Wedge for IBM Terminals 31xx, 32xx, 34xx, 37xx make only keyboardSelect KBD-IBM-MSet K

Página 136 - 128 QuickScan® QD2100

Symbologies212 QuickScan® QD2100Datalogic 2 of 5 — cont.Datalogic 2 of 5 StitchingThis option enables/disables stitching for Datalogic 2 of 5 labels.

Página 137 - UPC/EAN Correlation

CodabarProduct Reference Guide 213CodabarThe following options apply to the Codabar symbology.Codabar Enable/DisableWhen disabled, the reader

Página 138 - UPC/EAN Price Weight Check

Symbologies214 QuickScan® QD2100Codabar — cont.Codabar Check Character CalculationEnable this option to enables/disables calculation and verification

Página 139 - UPC-A Minimum Reads

CodabarProduct Reference Guide 215Codabar — cont.Codabar Check Character TransmissionEnable this option to transmit the check character along

Página 140 - Optional Add-ons

Symbologies216 QuickScan® QD2100Codabar — cont.Codabar Start/Stop Character SetThis option specifies the format of transmitted Codabar start/stop char

Página 141 - Add-Ons — cont

CodabarProduct Reference Guide 217Codabar — cont.Codabar Start/Stop Character MatchWhen enabled, this option requires that start and stop cha

Página 142

Symbologies218 QuickScan® QD2100Codabar — cont.Codabar Quiet ZonesThis feature specifies the number of quiet zones for Codabar labels. Quiet zones are

Página 143

CodabarProduct Reference Guide 219Codabar — cont.Codabar Minimum ReadsThis feature specifies the minimum number of consecutive times a Codaba

Página 144

Symbologies220 QuickScan® QD2100Codabar — cont.Codabar Decoding LevelDecoding Levels are used to configure a barcode symbology decoder to be very aggr

Página 145

CodabarProduct Reference Guide 221Codabar — cont.Codabar Decoding Level — cont.ENTER/EXIT PROGRAMMING MODECodabar Decoding Level = 1Codabar D

Página 146

Global Interface FeaturesProduct Reference Guide 15Global Interface FeaturesThe following interface features are configurable by all interfac

Página 147

Symbologies222 QuickScan® QD2100Codabar — cont.Codabar Length ControlThis feature specifies either variable length decoding or fixed length decoding f

Página 148

CodabarProduct Reference Guide 223Codabar — cont.Codabar Set Length 1This feature specifies one of the barcode lengths for Codabar Length Con

Página 149

Symbologies224 QuickScan® QD2100Codabar — cont.Codabar Set Length 1 — cont.ENTER/EXIT PROGRAMMING MODESelect Codabar Length 1 SettingMake a mistake? S

Página 150

CodabarProduct Reference Guide 225Codabar — cont.Codabar Set Length 2This feature specifies one of the barcode lengths for Codabar Length Con

Página 151 - GS1 DataBar Omnidirectional

Symbologies226 QuickScan® QD2100Codabar — cont.Codabar Set Length 2 — cont.ENTER/EXIT PROGRAMMING MODESelect CodabarLength 2 SettingMake a mistake? Sc

Página 152 - 144 QuickScan® QD2100

CodabarProduct Reference Guide 227Codabar — cont.Codabar Interdigit RatioThis feature specifies the ratio between an intercharacter space and

Página 153 - GS1 DataBar Expanded

Symbologies228 QuickScan® QD2100Codabar — cont.Codabar Interdigit Ratio — cont.ENTER/EXIT PROGRAMMING MODECodabar Interdigit Ratio = 6Codabar Interdig

Página 154 - GS1 DataBar Expanded — cont

CodabarProduct Reference Guide 229Codabar — cont.Codabar Character CorrelationWhen correlation is enabled, the barcode reader will combine la

Página 155

Symbologies230 QuickScan® QD2100Codabar StitchingThis option enables/disables stitching for Codabar labels. When parts of a Codabar bar-code are prese

Página 156

Code 11Product Reference Guide 231Code 11The following options apply to the Code 11 symbology.Code 11 Enable/DisableWhen disabled, the reader

Página 157

Interfaces16 QuickScan® QD2100USB Suspend Mode This setting enables/disables the ability of USB interfaces to enter suspend mode.ENTER/EXIT PROGRAMMIN

Página 158

Symbologies232 QuickScan® QD2100Code 11 — cont.Code 11 Check Character CalculationThis option enables/disables calculation and verification of optiona

Página 159

Code 11Product Reference Guide 233Code 11 — cont.Code 11 Check Character TransmissionThis feature enables/disables transmission of an optiona

Página 160 - GS1 DataBar Limited

Symbologies234 QuickScan® QD2100Code 11 — cont.Code 11 Minimum ReadsThis feature specifies the minimum number of consecutive times a Code 11 label mus

Página 161 - GS1 DataBar Limited — cont

Code 11Product Reference Guide 235Code 11 — cont.Code 11 Length ControlThis feature specifies either variable length decoding or fixed length

Página 162 - Code 39 Enable/Disable

Symbologies236 QuickScan® QD2100Code 11 — cont.Code 11 Set Length 1This feature specifies one of the barcode lengths for Code 11 Length Control. Lengt

Página 163 - Code 39 — cont

Code 11Product Reference Guide 237Code 11 — cont.Code 11 Set Length 1 — cont.ENTER/EXIT PROGRAMMING MODESelect Code 11 Set Length 1 SettingMa

Página 164

Symbologies238 QuickScan® QD2100Code 11 — cont.Code 11 Set Length 2This feature specifies one of the barcode lengths for Code 11 Length Control. Lengt

Página 165

Code 11Product Reference Guide 239Code 11 — cont.Code 11 Set Length 2 — cont.ENTER/EXIT PROGRAMMING MODESelect Code 11 Length 2 SettingMake a

Página 166

Symbologies240 QuickScan® QD2100Code 11 — cont.Code 11 Interdigit RatioThis feature specifies the ratio between an intercharacter space and module for

Página 167

Code 11Product Reference Guide 241Code 11 — cont.Code 11 Interdigit Ratio — cont.ENTER/EXIT PROGRAMMING MODECode 11 Interdigit Ratio = 6Code

Página 168

Product Reference Guide 17Chapter 4General FeaturesDouble Read TimeoutTo prevent a double read of the same label, the Double Read Timeout sets the min

Página 169

Symbologies242 QuickScan® QD2100Code 11 Decoding LevelDecoding Levels are used to configure a barcode symbology decoder to be very aggressive to very

Página 170

Code 11Product Reference Guide 243Code 11 — cont.Code 11 Decoding Level — cont.ENTER/EXIT PROGRAMMING MODECodabar Decoding Level = 1Codabar D

Página 171

Symbologies244 QuickScan® QD2100Code 11 — cont.Code 11 Character CorrelationWhen correlation is enabled, the barcode reader will combine label data fr

Página 172

Code 11Product Reference Guide 245Code 11 StitchingThis option enables/disables stitching for Code 11 labels. When parts of a Code 11 bar-cod

Página 173

Symbologies246 QuickScan® QD2100Standard 2 of 5The following options apply to the Standard 2 of 5 symbology.Standard 2 of 5 Enable/DisableWhen disable

Página 174

Standard 2 of 5Product Reference Guide 247Standard 2 of 5 — cont.Standard 2 of 5 Check Character CalculationThis option enables/disables calc

Página 175

Symbologies248 QuickScan® QD2100Standard 2 of 5 — cont.Standard 2 of 5 Minimum ReadsThis feature specifies the minimum number of consecutive times a S

Página 176

Standard 2 of 5Product Reference Guide 249Standard 2 of 5 — cont.Standard 2 of 5 Length ControlThis feature specifies either variable length

Página 177

Symbologies250 QuickScan® QD2100Standard 2 of 5 — cont.Standard 2 of 5 Set Length 1This feature specifies one of the barcode lengths for Standard 2 of

Página 178 - Code 39 Stitching

Standard 2 of 5Product Reference Guide 251Standard 2 of 5 — cont.Standard 2 of 5 Set Length 1 — cont.ENTER/EXIT PROGRAMMING MODESelect Standa

Página 179 - Code 32 Enable/Disable

General Features18 QuickScan® QD2100Double Read Timeout — continuedENTER/EXIT PROGRAMMING MODEDouble Read Timeout = 0.5 SecondDouble Read Timeout = 0.

Página 180 - Code 32 — cont

Symbologies252 QuickScan® QD2100Standard 2 of 5 — cont.Standard 2 of 5 Set Length 2This feature specifies one of the barcode lengths for Standard 2 of

Página 181 - Code 128

Standard 2 of 5Product Reference Guide 253Standard 2 of 5 — cont.Standard 2 of 5 Set Length 2 — cont.ENTER/EXIT PROGRAMMING MODESelect Standa

Página 182 - Code 128 — cont

Symbologies254 QuickScan® QD2100Standard 2 of 5 — cont.Standard 2 of 5 Character CorrelationWhen correlation is enabled, the barcode reader will combi

Página 183

Standard 2 of 5Product Reference Guide 255Standard 2 of 5 StitchingThis option enables/disables stitching for Standard 2 of 5 labels. When pa

Página 184

Symbologies256 QuickScan® QD2100ISBT 128The following options apply to the ISBT 128 symbology.ISBT 128 Enable/DisableEnables/Disables ability of image

Página 185

ISBT 128Product Reference Guide 257ISBT 128 — cont.ISBT 128 Force ConcatenationWhen enabled, this feature forces all ISBT 128 labels to be co

Página 186

Symbologies258 QuickScan® QD2100Code 4The following options apply to the Code 4 symbology.Code 4 Enable/DisableEnables/Disables ability of imager to d

Página 187

Code 4Product Reference Guide 259Code 4 — cont.Code 4 Check Character TransmissionThis feature enables/disables transmission of an optional C

Página 188

Symbologies260 QuickScan® QD2100Code 5The following options apply to the Code 5 symbology.Code 5 Enable/DisableEnables/Disables ability of imager to d

Página 189

Code 5Product Reference Guide 261Code 5 — cont.Code 5 Check Character TransmissionThis feature enables/disables transmission of an optional C

Página 190

Label Gone TimeoutProduct Reference Guide 19Label Gone TimeoutThis feature sets the time after the last label segment is seen before the read

Página 191

Symbologies262 QuickScan® QD2100Code 4 and Code 5 Common Configuration ItemsThe following options apply to both Code 4 and Code 5 symbologies.Code 4 a

Página 192

Code 4 and Code 5 Common Configuration ItemsProduct Reference Guide 263Code 4 and Code 5 Common Configuration Items — cont.Code 4 and 5 Decod

Página 193

Symbologies264 QuickScan® QD2100Code 4 and Code 5 Common Configuration Items — cont.Code 4 and Code 5 Minimum ReadsThis feature specifies the minimum

Página 194

Follett 2 of 5Product Reference Guide 265Follett 2 of 5The following options apply to the Follett 2 of 5 symbology.Follett 2 of 5 Enable/Disa

Página 195 - GS1-128 Enable

Symbologies266 QuickScan® QD2100NOTES

Página 196 - Interleaved 2 of 5 (I 2 of 5)

Product Reference Guide 267Appendix ATechnical SpecificationsTable 35 contains Physical and Performance Characteristics, User Environment and Regulato

Página 197

268 QuickScan® QD2100Decode CapabilityUPC/EAN/JAN, P2 /P5 GS1-128 add-ons; Code 39; Code 39 Full ASCII; Code 32 (Italian Pharmacode); Code 128; ISBT 1

Página 198 - 190 QuickScan® QD2100

Standard Cable PinoutsProduct Reference Guide 269Standard Cable PinoutsFigure 7 and Table 36 provide standard pinout information for the imag

Página 199 - I 2 of 5 Minimum Reads

270 QuickScan® QD2100NOTES

Página 200 - 2 of 5 Decoding Level

Product Reference Guide 271Appendix BStandard DefaultsThe most common configuration settings are listed in the “Default” column of Table 37.The settin

Página 201 - 2 of 5 Decoding Level — cont

General Features20 QuickScan® QD2100Label Gone Timeout — cont.ENTER/EXIT PROGRAMMING MODESelect Label Gone Timeout SettingMake a mistake? Scan the CAN

Página 202 - I 2 of 5 Length Control

272 QuickScan® QD2100RS-232Baud Rate960041Data Bits8 Data Bits43Stop Bits1 Stop Bit44ParityNone45Handshaking ControlDisable46RS-232/USB-COMIntercharac

Página 203 - I 2 of 5 Set Length 1

Product Reference Guide 273Data EditingGlobal Prefix/SuffixNo Global PrefixGlobal Suffix = 0x0D (CR)90Global AIM IDDisable92Label ID ControlD

Página 204 - 06 = Length 1 is 6 Characters

274 QuickScan® QD2100EAN-13 ISBN ConversionDisable122EAN 13 Minimum Reads1123EAN 8EAN 8 Enable/DisableEnable124EAN 8 Check Character TransmissionSend1

Página 205 - I 2 of 5 Set Length 2

Product Reference Guide 275GS1 DataBar Expanded Set Length 11148GS1 DataBar Expanded Set Length 274150GS1 DataBar LimitedGS1 DataBar Limited

Página 206 - I 2 of 5 Set Length 2 — cont

276 QuickScan® QD2100Expand Code 128 to Code 39Don’t Expand173Code 128 Check Character TransmissionSend174Code 128 Quiet ZonesAuto176Code 128 Minimum

Página 207

Product Reference Guide 277Datalogic 2 of 5 Set Length 112205Datalogic 2 of 5 Set Length 2100207Datalogic 2 of 5 Character CorrelationDisable

Página 208 - I 2 of 5 Stitching

278 QuickScan® QD2100Code 11 Interdigit Ratio4240Code 11 Decoding Level3242Code 11 Character CorrelationDisable244Code 11 StitchingDisable245Standard

Página 209 - Datalogic 2 of 5

Product Reference Guide 279Code 4 and Code 5 Common Configuration ItemsCode 4 and 5 Decoding Level3262Code 4 and Code 5 Minimum Reads1264Foll

Página 210 - Datalogic 2 of 5 — cont

280 QuickScan® QD2100Default ExceptionsTable 37 lists standard default settings as applied to a standard RS-232 interface. Table 38 provides a listing

Página 211

Default ExceptionsProduct Reference Guide 281EAN8/P2 Label ID Character(s) BEAN8/P5 Label ID Character(s) BEAN8/GS1-128 Label ID Character(s)

Página 212

LED and Beeper IndicatorsProduct Reference Guide 21LED and Beeper IndicatorsPower On AlertDisables or enables the indication (from the Beeper

Página 213

282 QuickScan® QD2100UPCE/P5 Label ID Character(s) IEAN8/P2 Label ID Character(s) JEAN8/P5 Label ID Character(s) KEAN8/GS1-128 Label ID Character(s) *

Página 214

Product Reference Guide 283Appendix CLED and Beeper IndicationsThe imager’s beeper sounds and its LED illuminates to indicate various functions or er-

Página 215

284 QuickScan® QD2100LED and Beeper IndicationsINDICATION DESCRIPTION LED BEEPERPower-up BeepThe imager is in the process of pow-ering-up.Imager beeps

Página 216

Error CodesProduct Reference Guide 285Error CodesUpon startup, if the imager sounds a long tone, this means the imager has not passed its aut

Página 217

286 QuickScan® QD2100NOTES

Página 218 - 210 QuickScan® QD2100

Product Reference Guide 287Appendix DSample BarcodesThe sample barcodes in this appendix are typical representations for their symbology types. UP

Página 219

288 QuickScan® QD2100Sample Barcodes — continuedCode 32 CodabarCode 93 Code 11

Página 220

GS1 DataBar (RSS)Product Reference Guide 289GS1 DataBar (RSS)GS1 DataBar-14NOTEGS1 DataBar variants must be enabled to read the barcodes belo

Página 221 - Codabar Enable/Disable

290 QuickScan® QD2100NOTES

Página 222 - Codabar — cont

Product Reference Guide 291Appendix EKeypadUse the barcodes in this appendix to enter numbers as you would select digits/characters from a keypad.0123

Página 223

Product Reference Guide1Table of ContentsChapter 1. Introduction ...

Página 224

General Features22 QuickScan® QD2100Good Read: When to IndicateThis feature specifies when the reader will provide indication (beep and/or flash its g

Página 225

292 QuickScan® QD21006789ABC

Página 226

Product Reference Guide 293DEF

Página 227

294 QuickScan® QD2100NOTES

Página 228

Product Reference Guide 295Appendix FScancode TablesControl Character EmulationControl character emulation selects from different scancode tables as l

Página 229

Product Reference Guide296Interface Type PC AT PS/2 or USB-KeyboardTable 39. Scancode Set When Control Character is 00 or 01Extended characters (sky

Página 230

Product Reference Guide297Interface Type PC AT PS/2 or USB-Keyboard — cont.Table 40. Scancode Set When Control Character is 02x0 x1 x2 x3 x4 x5 X6 x7

Página 231

Product Reference Guide298Interface type PC AT PS/2 Alt Mode or USB-Keyboard Alt ModeTable 41. Scancode Set When Control Character is 00 or 01x0 x1

Página 232

Product Reference Guide299Interface type PC AT PS/2 Alt Mode or USB-Keyboard Alt Mode — cont.Table 42. Scancode Set When Control Character is 02x0 x1

Página 233

Product Reference Guide300Digital InterfaceTable 43. Scancode Set When Control Character is 00 or 01X0 x1 x2 x3 x4 x5 x6 x7 x8 x9 xA xB xC xD xE xF0

Página 234

Product Reference Guide301Digital Interface — cont.Table 44. Scancode Set When Control Character is 02X0 x1 x2 x3 x4 x5 x6 x7 x8 x9 xA xB xC xD xE xF0

Página 235

LED and Beeper IndicatorsProduct Reference Guide 23Good Read Beep TypeSpecifies whether the good read beep has a mono or bitonal beep sound.E

Página 236

Product Reference Guide302IBM31xx 102-keyTable 45. Scancode Set When Control Character is 00 or 01X0 x1 x2 x3 x4 x5 x6 x7 x8 x9 xA xB xC xD xE xF0x

Página 237

Product Reference Guide303IBM31xx 102-key — cont.Table 46. Scancode Set When Control Character is 02X0 x1 x2 x3 x4 x5 x6 x7 x8 x9 xA xB xC xD xE xF0xA

Página 238 - Codabar Stitching

Product Reference Guide304IBM XTTable 47. Scancode Set When Control Character is 00 or 01X0 x1 x2 x3 x4 x5 x6 x7 x8 x9 xA xB xC xD xE xF0xNULLC(S)+@

Página 239 - Code 11 Enable/Disable

Product Reference Guide305IBM XT — cont.Table 48. Scancode Set When Control Character is 02X0 x1 x2 x3 x4 x5 x6 x7 x8 x9 xA xB xC xD xE xF0xArÈ ArÇ Al

Página 240 - Code 11 — cont

306 QuickScan® QD2100Microsoft Windows Codepage 1252Windows-1252 is a character encoding of the Latin alphabet, used by default in the leg-acy compone

Página 241

Microsoft Windows Codepage 1252Product Reference Guide 307NOTES

Página 242

308 QuickScan® QD2100NOTES

Página 243

Product Reference Guide 309IndexBbar codesRS-232baud rate 79RS-232 parametersparity 256, 258, 260, 263, 265barcodescancel 291numeric barcodes 291RS-23

Página 244

310 QuickScan® QD2100Nnumbers lock key 71PPerformance Characteristics 267Physical Characteristics 267Pitch – Good Read, Beeper 23, 24Pitch Tolerance 2

Página 245

ASCII ChartASCII Char.Hex No.ASCII Char.Hex No.ASCIIChar.Hex No.ASCIIChar.HexNo.NULSOHSTXETXEOTENQACKBELBSHTLFVTFFCRSOSIDLEDC1DC2DC3DC4NAKSYNETBCANEMS

Página 246

General Features24 QuickScan® QD2100Good Read Beep FrequencyAdjusts the good read beep to sound at a selectable low, medium or high frequency, se-lect

Página 247

AustraliaDatalogic Scanning Pty LtdTelephone: [61] (2) 9870 [email protected] and BeneluxDatalogic Scanning SarlTelephone: [3

Página 248

LED and Beeper IndicatorsProduct Reference Guide 25Good Read Beep Length — continuedENTER/EXIT PROGRAMMING MODEGood Read Beep Length = 80 mse

Página 249

General Features26 QuickScan® QD2100Good Read Beep VolumeSelects the beeper volume (loudness) upon a good read beep. There are three selectable volume

Página 250 - Code 11 Decoding Level

LED and Beeper IndicatorsProduct Reference Guide 27Good Read LED DurationThis feature specifies the amount of time that the Good Read LED rem

Página 251

General Features28 QuickScan® QD2100Good Read LED Duration — cont.ENTER/EXIT PROGRAMMING MODESelect Good Read LED Duration SettingMake a mistake? Scan

Página 252

Scanning FeaturesProduct Reference Guide 29Scanning FeaturesScan ModeSelects the scan operating mode for the reader. Selections are:Trigger S

Página 253 - Code 11 Stitching

General Features30 QuickScan® QD2100Scan Mode — continuedENTER/EXIT PROGRAMMING MODEScan Mode = Trigger SingleScan Mode = Trigger Hold MultipleScan Mo

Página 254 - Standard 2 of 5

Scanning FeaturesProduct Reference Guide 31Stand Mode Triggered TimeoutThis feature specifies the time to remain in Trigger Single mode after

Página 255 - Standard 2 of 5 — cont

2QuickScan® QD2100RS-232 Standard Factory Settings ...

Página 256

General Features32 QuickScan® QD2100Stand Mode Triggered Timeout — continuedENTER/EXIT PROGRAMMING MODEStand Mode Triggered Timeout = 6 SecondsStand M

Página 257

Scanning FeaturesProduct Reference Guide 33Scanning Active TimeThis setting specifies the amount of time that the reader stays in scan ON sta

Página 258

General Features34 QuickScan® QD2100Scanning Active Time — cont.ENTER/EXIT PROGRAMMING MODESelect Scanning Active Time SettingMake a mistake? Scan the

Página 259

Flash On TimeProduct Reference Guide 35Flash On TimeThis feature specifies the ON time for the indicator LED while in Flash Mode. The se-lect

Página 260

General Features36 QuickScan® QD2100Flash On Time — cont.ENTER/EXIT PROGRAMMING MODESelect Flash ON Time SettingMake a mistake? Scan the CANCEL barcod

Página 261

Flash Off TimeProduct Reference Guide 37Flash Off TimeThis feature specifies the OFF time for the indicator LED while in Flash Mode. The se-l

Página 262

General Features38 QuickScan® QD2100Flash Off Time — cont.ENTER/EXIT PROGRAMMING MODESelect Flash OFF Time SettingMake a mistake? Scan the CANCEL barc

Página 263 - Standard 2 of 5 Stitching

Stand Mode SensitivityProduct Reference Guide 39Stand Mode SensitivitySets the sensitivity level for stand mode wakeup. Choices are low, medi

Página 264 - ISBT 128

General Features40 QuickScan® QD2100Green Spot DurationSpecifies the duration of the good read pointer beam after a good read.ENTER/EXIT PROGRAMMING M

Página 265 - ISBT 128 Force Concatenation

Product Reference Guide 41Chapter 5RS-232 ONLY InterfaceIntroductionUse the programming barcodes in this chapter if modifications to the standard RS-2

Página 266 - Code 4 Enable/Disable

Product Reference Guide3Case Conversion ...

Página 267 - Code 4 — cont

RS-232 ONLY Interface42 QuickScan® QD2100Baud Rate — continuedENTER/EXIT PROGRAMMING MODEBaud Rate = 9600Baud Rate = 19,200Baud Rate = 38,400Baud Rate

Página 268 - Code 5 Enable/Disable

Data BitsProduct Reference Guide 43Data BitsThis parameter allows the reader to interface with devices requiring a 7-bit or 8-bit ASCII proto

Página 269 - Code 5 — cont

RS-232 ONLY Interface44 QuickScan® QD2100Stop BitsThe stop bit(s) at the end of each transmitted character marks the end of transmission of one charac

Página 270 - Code 4 and 5 Decoding Level

ParityProduct Reference Guide 45ParityThis feature specifies parity required for sending and receiving data. A parity check bit is the most s

Página 271

RS-232 ONLY Interface46 QuickScan® QD2100Handshaking ControlThe data interface consists of an RS-232 port designed to operate either with or without t

Página 272 - 264 QuickScan® QD2100

Product Reference Guide 47Chapter 6RS-232/USB-Com InterfacesIntroductionThe programming barcodes in this chapter allow modifications to the standard R

Página 273 - Follett 2 of 5

RS-232/USB-Com Interfaces48 QuickScan® QD2100Intercharacter DelayThis parameter specifies the intercharacter delay between the end of one character an

Página 274 - 266 QuickScan® QD2100

Intercharacter DelayProduct Reference Guide 49Intercharacter Delay — cont.ENTER/EXIT PROGRAMMING MODEIntercharacter Delay = No DelaySelect In

Página 275 - Appendix A

RS-232/USB-Com Interfaces50 QuickScan® QD2100Beep On ASCII BELWhen this parameter is enabled, the reader issues a beep when a <BEL> character is

Página 276 - 268 QuickScan® QD2100

ACK NAK OptionsProduct Reference Guide 51ACK NAK OptionsThis enables/disables the ability of the reader to support the RS-232 ACK/NAK proto-c

Página 277 - Standard Cable Pinouts

4QuickScan® QD2100Code 39 ...

Página 278 - 270 QuickScan® QD2100

RS-232/USB-Com Interfaces52 QuickScan® QD2100ACK CharacterThis setting specifies an ASCII character or hex value to be used as the ACK character. ASCI

Página 279 - Appendix B

ACK NAK OptionsProduct Reference Guide 53ACK Character — cont.ENTER/EXIT PROGRAMMING MODESelect ACK Character SettingDEFAULT0x06 ‘ACK’ Charac

Página 280

RS-232/USB-Com Interfaces54 QuickScan® QD2100NAK CharacterThis setting specifies an ASCII character or hex value to be used as the NAK character. ASCI

Página 281

ACK NAK OptionsProduct Reference Guide 55NAK Character — cont.ENTER/EXIT PROGRAMMING MODESelect NAK Character SettingDEFAULT0x15 ‘NAK’ Charac

Página 282

RS-232/USB-Com Interfaces56 QuickScan® QD2100ACK NAK Timeout ValueThis option specifies the amount of time the reader waits for an ACK character from

Página 283

ACK NAK OptionsProduct Reference Guide 57ACK NAK Timeout Value — cont.ENTER/EXIT PROGRAMMING MODESelect ACK NAK Timeout Value SettingMake a m

Página 284 - Interleaved 2 of 5

RS-232/USB-Com Interfaces58 QuickScan® QD2100ACK NAK Retry CountThis feature specifies the number of times the reader retries a label transmission due

Página 285

ACK NAK OptionsProduct Reference Guide 59ACK NAK Retry Count — cont.ENTER/EXIT PROGRAMMING MODESelect ACK NAK Retry Count SettingMake a mista

Página 286

RS-232/USB-Com Interfaces60 QuickScan® QD2100ACK NAK Error HandlingThis feature specifies the method the reader uses to handle receive errors detected

Página 287

Indicate Transmission FailureProduct Reference Guide 61Indicate Transmission FailureThis option enables/disables the reader’s ability to soun

Página 288 - Default Exceptions

Product Reference Guide5Codabar Check Character Calculation ...

Página 289 - Interface: RS232-OPOS

RS-232/USB-Com Interfaces62 QuickScan® QD2100Disable CharacterSpecifies the value of the RS-232 host command used to disable the reader.ASCII characte

Página 290 - 282 QuickScan® QD2100

Disable CharacterProduct Reference Guide 63Disable Character — cont.ENTER/EXIT PROGRAMMING MODESelect Disable Character SettingDEFAULT0x44 =

Página 291 - Appendix C

RS-232/USB-Com Interfaces64 QuickScan® QD2100Enable CharacterSpecifies the value of the RS-232 host command used to enable the reader.ASCII characters

Página 292 - LED and Beeper Indications

Enable CharacterProduct Reference Guide 65Enable Character — cont.ENTER/EXIT PROGRAMMING MODESelect Enable Character SettingDEFAULT0x45 = Ena

Página 293 - Error Codes

RS-232/USB-Com Interfaces66 QuickScan® QD2100NOTES

Página 294 - 286 QuickScan® QD2100

Product Reference Guide 67Chapter 7Keyboard InterfaceIntroductionUse the programming barcodes in this chapter to select options for USB Keyboard and W

Página 295 - Appendix D

Keyboard Interface68 QuickScan® QD2100Country ModeThis feature specifies the country/language supported by the keyboard.Only the following interfaces

Página 296 - Code 11

Country ModeProduct Reference Guide 69Country Mode — continuedENTER/EXIT PROGRAMMING MODECountry Mode = DenmarkSupports only the interfaces l

Página 297 - GS1 DataBar (RSS)

Keyboard Interface70 QuickScan® QD2100Country Mode — continuedENTER/EXIT PROGRAMMING MODECountry Mode = PolandSupports only the interfaces listed in t

Página 298 - 290 QuickScan® QD2100

Caps Lock StateProduct Reference Guide 71Caps Lock StateThis option specifies the format in which the reader sends character data. This appli

Página 299 - Appendix E

6QuickScan® QD2100Appendix B. Standard Defaults ... 271Def

Página 300 - 292 QuickScan® QD2100

Keyboard Interface72 QuickScan® QD2100Send Control CharactersThis feature Specifies how the reader transmits ASCII control characters to the host. Ref

Página 301

Wedge Quiet IntervalProduct Reference Guide 73Wedge Quiet IntervalThis option specifies the amount of time to look for keyboard activity befo

Página 302 - 294 QuickScan® QD2100

Keyboard Interface74 QuickScan® QD2100Wedge Quiet Interval — cont.ENTER/EXIT PROGRAMMING MODESelect Wedge Quiet Interval SettingMake a mistake? Scan t

Página 303 - Appendix F

Intercharacter DelayProduct Reference Guide 75Intercharacter DelayThis parameter specifies the intercharacter delay between the end of one ch

Página 304 - Product Reference Guide

Keyboard Interface76 QuickScan® QD2100Intercharacter Delay — cont.ENTER/EXIT PROGRAMMING MODEIntercharacter Delay = No DelaySelect Intercharacter Dela

Página 305

Intercode DelayProduct Reference Guide 77Intercode DelaySpecifies the delay between labels transmitted to the host for this interface. The se

Página 306

Keyboard Interface78 QuickScan® QD2100Intercode Delay — cont.ENTER/EXIT PROGRAMMING MODESet Intercode DelayMake a mistake? Scan the CANCEL barcode to

Página 307

USB Keyboard SpeedProduct Reference Guide 79USB Keyboard SpeedThis option specifies the USB poll rate for a USB keyboard.NOTEThis feature app

Página 308 - Digital Interface

Keyboard Interface80 QuickScan® QD2100USB Keyboard Speed — continuedENTER/EXIT PROGRAMMING MODEUSB Keyboard Speed = 6msUSB Keyboard Speed = 7msUSB Key

Página 309 - Digital Interface — cont

Product Reference Guide 81Chapter 8USB-OEM InterfaceIntroductionFeature settings for USB interfaces differ depending upon which host type the reader w

Página 310 - IBM31xx 102-key

Product Reference Guide 1Chapter 1IntroductionAbout this GuideThis Product Reference Guide (PRG) is provided for users seeking advanced technical info

Página 311 - IBM31xx 102-key — cont

USB-OEM Interface82 QuickScan® QD2100USB-OEM Device UsageThe USB-OEM protocol allows for the reader to be identified as one of two different types of

Página 312

Product Reference Guide 83Chapter 9IBM 46XX InterfaceIntroductionUse the barcodes in this section to configure programmable features for available IBM

Página 313 - IBM XT — cont

IBM 46XX Interface84 QuickScan® QD210046xx Number of Host ResetsSpecifies how many consecutive resets are processed before the reader starts a five-se

Página 314 - 306 QuickScan® QD2100

46xx Number of Host ResetsProduct Reference Guide 8546xx Number of Host Resets — cont.ENTER/EXIT PROGRAMMING MODE46xx Number of Host Resets =

Página 315

IBM 46XX Interface86 QuickScan® QD210046xx Number of Host Resets — cont.ENTER/EXIT PROGRAMMING MODE46xx Number of Host Resets = 1346xx Number of Host

Página 316 - 308 QuickScan® QD2100

Transmit Labels in Code 39 FormatProduct Reference Guide 87Transmit Labels in Code 39 FormatThis feature enable/disables translation to Code

Página 317 - Product Reference Guide 309

IBM 46XX Interface88 QuickScan® QD2100NOTES

Página 318 - 310 QuickScan® QD2100

Product Reference Guide 89Chapter 10Data EditingData Editing OverviewWhen a barcode is scanned, additional information can be sent to the host compute

Página 319 - ASCII Chart

Data Editing90 QuickScan® QD2100Please Keep In Mind...• Modifying a message string is not a mandatory requirement. Data editing is sophisticated feat

Página 320

Global Prefix/SuffixProduct Reference Guide 916. Scan the ENTER/EXIT barcode once again to exit Programming Mode.7. The resulting message str

Comentários a estes Manuais

Sem comentários