Datalogic Scanning POWERSCAN PD7100 Manual do Utilizador Página 260

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 324
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 259
Symbologies
252 PowerScan
®
PD7100 Corded
Standard 2 of 5 — cont.
Standard 2 of 5 Minimum Reads
This feature specifies the minimum number of consecutive times a Standard 2 of 5 label
must be decoded before it is accepted as good read.
Standard 2 of 5 Decoding Level
ENTER/EXIT PROGRAMMING MODE
Standard 2 of 5 Minimum Reads = 1
Standard 2 of 5 Minimum Reads = 2
Standard 2 of 5 Minimum Reads = 3
Standard 2 of 5 Minimum Reads = 4
DEFAULT
NOTE
The Standard 2 of 5 Decoding Level feature is set using
2 of 5 Decoding
Level on page 196
.
Vista de página 259
1 2 ... 255 256 257 258 259 260 261 262 263 264 265 ... 323 324

Comentários a estes Manuais

Sem comentários